Multi-Meters for: Conductivity / Salinity / Resistivity/ TDS/ Temperature/
 pH / mV / ion /Dissolved Oxygen
USB - Datalogging-Free Software


C6010 - multi-parameter analyser for pH, mV, conductivity, resistivity, salinity, TDS and Dissolved Oxygen
pH -2...+16 pH
mV ±2000 mV
Conductivity 0...2000 mS/cm
Resistivity 0...200 MΩ.cm
Salinity 0.0...70.0
TDS 0...100 g/l
DO 0...60 mg/l
0...600%
Air pressure: 600...1300 hPa
Temperature: -5...+105°C

C6030 - multi-parameter analyser for pH, mV, Ion, conductivity, resistivity, salinity, TDS and Dissolved Oxygen
pH -2...+16 pH
mV ±2000 mV
Ion 0.01 ng/l...100 g/l
Conductivity 0...2000 mS/cm
Resistivity 0...200 MΩ.cm
Salinity 0.0...70.0
TDS 0...100 g/l
DO 0...60 mg/l
0...600%
Air pressure: 600...1300 hPa
Temperature: -5...+105°C
 

These high resolution, electrochemistry meter do it all: Conductivity / Salinity / Resistivity/ TDS/ Temperature/ pH / mV / ion /Dissolved Oxygen. Complete with powerful set up options, Windows software and a host of other features which make it easy to use for almost any application in the field or in the lab. Includes data logger for storing up to 12000 readings. Kits come complete with electrodes, supplies, batteries instructions  and carrying case. Various combinations available (see below) for of pH, mV, conductivity, salinity, dissolved oxygen and temperature. The meter will work with any standard pH electrode, 2 electrode conductivity cell, Pt1000 or Pt100 thermometer. (note that DO probes from other manufacturers are not readily interchangeable between meters. The C6010 uses a galvanic probe. The models C6020 previously listed here has been discontinued and the model C6010 now incorporates all the feature of that model.)
 
 
Model Specification Multi Parameter meter
Modes Resolution
conductivity:
cell constant 1
0 - 0.001 uS/cm - 20 mS/cm 0.001 uS/cm
cell constant 0.1 0.01 uS/cm - 200mS/cm
cell constant 10 0.1 uS/cm - 2000 mS/cm
Accuracy 0.5% f.s. of range  
Calibration 1...3 points  
Standards 0.01/0.1/1M KCl
3 user specified
 
Temperature compensation -5...+105°C  
Reference temperature 20° or 25°C  
Temperature coefficient natural waters (EN27888)  
Resistivity  
cell constant 0.1 100 Ohm.cm 1 Ohm.cm
cell constant 1 10 Ohm.cm
cell constant 10 1 Ohm.cm
TDS:  
    cell constant 0.1 0.01 mg/l - 20 g/l 0.01 ng/l
    cell constant 1 0.01 mg/l - 100 g/l
    cell constant 10 0.1 mg/l - 100 g/l
Salinity: 0 - 70 ppt 0.1 ppt
    Degs C - 30 to + 130 0.1 deg. C
Temp: Range: -5...+105°C 0.1°C
  Accuracy: 0.3°C  
pH:
Range - 2 - 16 0.001 pH
Accuracy 0.1% ± 1 digit  
Calibration 1...5 points  
Buffers 9 pre-programmed
5 user specified
 
Temperature compensation -5...+105°C  
ISO-pH 6...8 pH  
Slope 80...120%  
Zero point (Eo) ±999 mV  
mV +/- 2000 mV 0.1 mV
Dissolved Oxygen    
Range 0 - 60 mg/l  0.01 mg/l, 0.1% O2
Saturation 0-600%  
Accuracy 1% ± 1 digit  
Compensation     
Air Pressure (600...1300 hPa)
Salinity (0...40)
Temperature(0...50°C)
 
Inputs
    Electrodes BNC
    Temperature Banana
   
Accuracy
    Conductivity/O2 1% of reading
    pH mV 0.2% of reading
Temperature Compensation
    Conductivity/pH/mV 0 - 100 C automatic or manual
    Oxygen 0 - 50 C auto
Calibration
    Cell Constant 0.1, 1.0, 10.0
    Temp Coeff NaCl Curve
    Standards 3 pre programmed
    Ref Temp 20 or 25 degs C
    Temperature +/ 10 degs C
    pH Buffers 9 pre-programmed
    ISO pH 6 - 8 pH
    Slope 80...120%
    mV +/- 100 mV
    Oxygen 1 points
 General Specifications
    Memory Storage memory for up to 12000 values + date and time.
    Display 122 x 32 pixels LCD
    Power

4x1.2 V, AA, NiMH
DC line 9 - 15 V

100...240 VAC, 50/60 Hz

    Dimensions 12 x 25 x 5 cms
    Weight 600 g
 
General Specifications
GLP protocol Built in
Display Hold Included
Plotter 1800 - 3600 points
Recorder output 0 - 2 volts
USB Baud rate - 300 to 9600 bps, bi-directional
interval 1 - 9999 s
Power Supply
AC line 110/220V 50/60Hz
DC line 9 - 15 Volts DC
NiMH batteries 4 x 1.2 Volts AA size
Dimensions 12 x 25 x 5 cms
Weight 600 g
Ordering Information C6000 series     Choose, configure and order online -
 
Model C6010 pH mV conductivity resistivity salinity TDS and temperature air pressure & Dissolved Oxygen - meter and software only  $775.00
Model C6010T kit with electrodes DO, pH, conductivity and solutions $1175.00  
 
Model C6030 pH mV ion conductivity resistivity salinity TDS temperature air pressure Dissolved Oxygen - Meter and software only  $1275.00 buy on line
Model C6030T Kit with electrodes and solutions ISE electrodes sold separately $1675.00  
 
CS C6010-SZ10T Dissolved oxygen kit meter, galvanic DO probe and solutions $970.00
     
Other ph Electrodes here, ISE electrodes here    

| Email | Home | Cells | Related Products |Ion selective electrodes |

Topac Inc. 231 CJC Highway, Suite 103 Cohasset MA 02025 USA
Tel: 781 740 8778 Fax: 781 740 8779

 
Copyright ©2016 by Topac Inc. - ALL RIGHTS RESERVED