16 Channel Programmable Data logger
for most types of Analog and Digital Sensors

  • 16 Channel Data Logger
  • Sensors with 0-20mA, 4-20mA output
  • Thermocouples K,J,T,N,R,S,B,E
  • Pt100/Pt1000 and NTC temperature sensors
  • Sensors with digital output (TTL levels), or analog (periodical), for counting measures, frequency and period (e.g. sensors for soil water content) t
  • Resistors and potentiometers to measure resistance and voltage relationship (e.g. vane anemometer)
  • Magnetic sensors with reed contact (e.g. open door)
  • Solar radiation sensors (pyranometers, albedometers, net-radiometers, luxmeters, pyrgeometers, duration of irradiation)
  • Sensors with open/close contact output (e.g. rain gauges, cup anemometers);
  • Sensors with RS485 output and MODBUS-RTU protocol;
  • HD2003 and HD52.3D series anemometers

The HD32MT.1 is a data logger capable of capturing and logging the values measured by a series of sensors connected to its inputs. The data logger is completely programmable by the user and is therefore very versatile. The application software, supplied with the instrument, features simple and intuitive programming using graphic interfaces, without the need to lear a programming language.

The values recorded by the instrument are easily transferred to a PC. The data logger can be configured to memorize the instant value, the minimum value, the maximum value, the average value and the standard deviation of the measurements. For measurements that require the counting of pulses, the total counted pulses can be stored. Different acquisition/recording intervals can be programmed per each input. Each recording includes acquisition date and time The data logger has a “flash” internal memory arranged in circular mode: when the memory is full the new data overwrite the older ones. The number of storable measurements depends on the number of sensors employed, on the type of measurement to be stored and on the fact that the sensors are acquired all at the same time or at different instants. For example, with 8 sensors captured at the same time, 100,000 records can be stored, each one composed of 8 instantaneous measurements. Data can also be directly recorded to a removable SD -type memory card with a capacity of 4 GB . The use of a memory card allows extending the memory capacity of the instrument, without loosing data when the memory is full.

Three data logger versions are available, depending on the communication with the PC

All versions can be equipped with a GSM module with which alarm SMS signals can be sent to mobile phones. The recorded data can be send by e-mail or to an FTP address.
The datalogger can be connected to most types of sensors, both analog and digital, used in industrial and environmental applications

Specifications

Data Aquistion Interval Programmable from 1 to 60 seconds / Programmable from 2 seconds to 24 hours
Storage Capacity 4 MB internal memory SD memory card reader up to 4 GB
Number of samples The storage of a record consisting of N values requires (4 x N) bytes of memory plus 8 bytes for the date and time.
Analog Signals 16 channels, each channel used as an single-wire (single-ended) input or alternatively two adjacent channels used as a differential input.
Measurement ranges ±25 mV, ±100 mV, ±1000 mV, ±2500 mV
Resolution: 16 bit,
Accuracy: 0.01% f.s.
Input impedance: 100 Mohm
Digital I/O Ports 8 ports, each configurable as an input for connecting a sensor or alarm output or sensor enabling.
TTL logic levels (0-‰ Vin<0.8 V, 1-‰ Vin>3 V)
Max. input voltage: 5.5 V
Inputs for high frequency pulse counting 2 inputs:
Frequency of pulses 100 kHz max.
TTL logic levels (0-‰ Vin<0.8 V, 1-‰ Vin>3 V)
Minimum pulse duration 10 μs
Inputs for number of potential-free contact opening/closing counting 2 insulated inputs
Switch frequency 50 Hz max.
Minimum opening or closing time 10 ms
RS 485 Connection RS485 port (up to 8 sensors can be connected) for Anemometers series HD2003 and HD52.3D and sensors with MODBUS-RTU protocol.
RS 232 Connection 2 x RS232 ports, one for connection to PC or to optional Radio Modem or to optional Ethernet module and one for connection to optional GSM module.
Sub-D 9-pole male connectors
Alarm Outputs 2 insulated voltage-free contact outputs Contact:
max. 1 A @ 30 Vdc resistive load.
You can configure the single digital I/O ports as alarm outputs
Auxilliary supply outputs +5V regulated, max. 500 mA
+Vsw (switched): with same value of the power input, active only during acquisition of measurements
Power supply / consumption 12..30V DC / 40mA @ 12V
Operating Conditions -20 ... 50 °C, 0 ... 85% RH no condensation
Case Material Coated aluminum
Size Weight 22x140x63 mm / About 1 kg
Storage Temperature -25 ... 65 °C

Ordering Information

Model Description US $  
HD32MT.1 16 Channel Data logger with software, SD card and instruction manual $2750.00
Options Call for configuration with radio modem and GSM and solar power options