Minitature panel meter thermometers range of indicators for use with K thermocouple and Pt100/1000 resistance thermometers RTDs) sensors with a unit resolution of 0.1 or 1 degree Celsius. Temperature ranges from - 50°C to 1150 °C are supported with an accuracy of ±1%, or better depending on the unit.
Sensor Type | Range | Resolution | Accuracy (15° to 25 °C ambient) | |
2448-1 | Thermocouple K-type | -50 ... +1150 °C (NiCr-Ni) | 1 °C | ±1 % ±1 digit (from -20 ...+550 °C and 920 ...1150 °C) ±1.5 % ±1 digit (from 550 ... 920 °C) |
2448-2 | RTD Pt100 2 wire | -200 ... +650 °C | 1 °C | ±0.5% ±1 digit±0.5 °C ±1 digit or ±1 °C ±1 digit±0.5% ±1 digit±0.5% ±1 digit |
2448-3 | RTD Pt100 2 wire | -60.0 ... +199.9 °C | 0.1 °C | |
2448-4 | RTD Pt1000 2 wire | -200 ... +650 °C | 1 °C | |
2448-5 | RTD Pt1000 2 wire | -60.0 ... +199.9 °C | 0.1 °C |
Model Number: | 2448-1,-2,-3,-4,-5 |
Offset compensation | The zero point offset of the sensor (e.g. due to long cables) can be compensated for by means of the spindle trimmer on the backside of the device. |
Display | 3½-digit, red 10 mm high LED display |
Scan rate | approx. 3 measurements / s |
Working Temperature | 0 ... 50 °C (permissible ambient temperature) |
Relative Humidity | -20 ... +70 °C |
Storage Temperature | 11.2mm LED |
Power Supply | 8 ... 20 V DC or 18 ... 29 V DC (standard) (set via soldering jumper) |
Current | 20 mA |
Panel Mounting | with VA-spring clamp. allowed panel thicknesses from 1 ... approx. 10 mm |
Connection Terminals | 4-pin screw-type/plug-in terminal for wire cross sections from 0.14 ... 1.5 mm² |
Protection Rating | IP54 ( front ) |
Housing | glass fibre reinforced Noryl, front panel PC |
Dimensions | 48 x 24 mm (W x H) (front frame) |
Cut Out | 45+0.5 x 21,7+0.5 mm (W x H) |
Mounting Depth | approx. 65 mm (incl. screw-type/plug-in terminal) |