Digital Panel Meters
Voltage/Current /AC/DC/
Process/RTD/Thermocouple
Asahi Digital panel meters from Asahi Keiki
offer impressive specifications, reliability
 and low cost for a variety of applications
 
digital panel meter      Features
  • BCD output
  • 4.5 digits
  • Scale-able display
  • Modular Panel Meter Systems
  • Choose AC or DC, Voltage or current modules
  • Thermocouples, Resistance thermometer options.
  • Power supply 5-12VDC or 12-24VDC
  • pdf data sheet
The A8000 is a small modular panel meter system with a selection of input and output cards to suit your application. Choose from 7 different input modules for AC, DC, Voltage and current, temperature, inputs. BCD output and external control options. The scale-able display means that you can adjust what is seen on the display to relate to the parameter you are measuring - for example if your pressure transducer produces 0-5V output for a pressure range of 0-100 psi then you can make the display read 0-100 for the input voltage 0-5V
A8000 Common Specifications
Specifications
Main Display Red LED 10 mm high
Conversion Rate 20 /sec
Maximum Display -19999 to 19999
Over-range indication 'OL' LED flashes
Zero Display Leading "zero" suppression
Decimal point Set to any position
Operating Temperature 0~ 50° C, 35 - 85% RH
Storage Temperature -10 ~+70° C, < 60% RH
Power Supply DC 5-12 Volts
DC 12-24 Volts
Power Consumption ~ 1.5W
Dimensions mm 48 x 24 x 96
Weight 100 g
Dielectric strength Power supply/ input terminal/ output terminal -DC 500V 1minute
Input terminal /output terminal - DC 500 V 1 minute
Case/each terminal - AC 1500 V 1 min.
Insulation resistance DC 500V more than 100 MOhm at above terminals
 
 INPUT MODULES
Base prices show include input measurement module, single display and power supply.
 DC Voltage Measurement
Code
1
Range Display
adjustable
Max Allowable
input voltage
Accuracy
11 ±199.99 mV offset ± 19999
Full scale 0 to ± 19999

± 50 V ±0.1% of reading + 2 digits base price
no output
$264.00
12 ±1.9999 V ± 50 V
13 ±19.999 V ± 250 V
14 ±199.99 V ± 250 V
 
DC Current Measurement Module
Code
2
Range Display
adjustable
input
protection
Accuracy
22 ±1.9999 mA offset ± 19999
Full scale 0 to ± 19999

± 50 mA ±0.1% of reading + 2 digits base price
no output
$264.00
22 ±19.999 mA ± 50 mA
24 ±199.99 mA ± 3 A
25 ±1999.9 mA ± 3 A
      
AC Voltage True RMS- Module
Code
4
Ranges Input
frequency
Display
adjustable
Max
input
voltage
Accuracy
11 199.99 mV 40Hz-1KHz offset ± 19999
Full scale
0 to ± 19999

50 V ±(0.2% of rdg +20 digit) base price
no output
$264.00
12 1.9999 mV 50 V
13 19.999 V 250 V
14 199.99 V 250 V
 
AC Current True RMS- Module
Code
5
Ranges Input
frequency
Display
adjustable
input
protection
Accuracy
23 19.999 mA 40Hz-1KHz offset ± 19999
Full scale
0 to ±1 9999

50 mA ±(0.5% of rdg +20 digit) base price
no output
$264.00
24 199.99 mA 3 A
25 1999.9 mA 3 A
 
Process
Code
B
Range Display
adjustable
input
protection
Accuracy  
1V 1 - 5V offset ± 19999
Full scale
0 to ± 19999

± 50 V ±0.1% of reading + 2 digits base price
no output
$249.00
2A 4 - 20 mA ± 50 mA

Thermcouple / RTD
Code C
Sensor
type
Measurement
Range
Maximum
Resolution
Accuracy
(23°C ± 5°C, 35 to 85%RH)
 
KA K -50.0 to 199.9°C
0.1°C ± (0.5% of FS) base price
no output
$249.00
KB K -50 to 1200°C 1°C ± (0.2% of FS)
J J -50 to 1000°C 1°C ± (0.2% of FS)
T T -50 to 400°C 1°C ± (0.2% of FS)
S S 0 to 1700°C 1°C ± (0.6% of FS)
R R -10 to 1700°C 1°C ± (0.4% of FS)
B B 100 to 1800°C 1°C ± (0.4% of FS)
Cold junction compensator accuracy : ± 2°C (10 to 40°C)
Sensor lead resistance : less than 50Ω
Linearzing method : Digital linearizing
Code D Sensor
type
Measurement
Range
Maximum
Resolution
Accuracy
(23°C ± 5°C, 35 to 85%RH)
 
PA PT 100Ω -100.0 to 199.9°C 0.1°C ± (0.15% of FS) base price
no output
$249.00
PB PT 100Ω -100 to 660°C 1°C ± (0.3% of FS)

 

BCD Output Specification
BCD output
Type of output Open collector or TTL
Logic Changeable
Output Rate DC30V 10mA (open collector)
Fanout 2 (TTL)
 
External Control
Hold Short hold and COM terminal (Hold ON)
Digital Zero (DZ) Short DZ and COM terminal
Peak Hold Short PH and com terminals (Peak Hold ON)

A8000 dimensions

   
Ordering and Configuration Information (pdf data sheet)
A8-x-y-z-Out Construct the part numbers by adding the numbers below. The base prices given above include the input board for that code each board contains several ranges shown as shown.
Affix x = 3 or 4 select power supply(How the unit is going to be powered)
3=DC 5-12V
4=DC 12-24V
  Configure
and
Order Online


configure and order online
Affix y = 1 or 2 Select Membrane switch on front panel 
1= with membrane switch functions visible, 
2=with blank membrane switch (keys present but not visible)
 

Affix z = input type

Select Input type
Code 1 =DC Voltage ± 199.99 mV to 1999.99V (4 ranges)
Code 2 = DC Current ±1.9999 mA
- ±1999.9 mA (4 ranges)
Code 4 = AC Voltage True RMS 199.99 mV - 199.99V (4 ranges)
Code 5 = AC Current True RMS19.999 mA
- ±1999.9 mA (3 ranges)
Code B = process 1-5V, 4-20mA

Code C Thermocouple
Codes D Resistance thermometer

 
Affix Out = 1 or 2 or 3

Output Selection 
1= No output, 
2= BCD TTL & external control
3= BCD Open & collector external control

Add
$0
$100.00
$100.00
 

Topac Inc. 231 CJC Highway, Suite 103 Cohasset MA 02025 USA
Tel: 781 740 8778 Fax: 781 740 8779
e-mail: sales@topac.com

| Home | E-mail | Online store | Inquiry form | Related |

This is a world wide web document page design layout and HTML code copyright ©2002-2014 by Topac Inc. - ALL RIGHTS RESERVED