Digital Panel Meters
Modular Configuration
Temperature/Thermocouple RTD
Asahi Digital panel meters from Asahi Keiki
offer impressive specifications, reliability
 and low cost for a variety of applications
 
A6000
     Features
  • Modular Panel Meter Systems
  • External Control
  • Choose AC or DC, Voltage or current modules
  • Inputs modules for resistance, RTD, thermocouples, frequency, and strain gages.
  • Output modules -setpoint- analog - RS232 & RS485
  • Universal power supply 90-264VAC or 6-60VDC
  • Dual display option for setpoint
The A6000 is a modular panel meter system with a selection of input and output cards to suit your application. Choose from 18 different input modules for AC, DC, Voltage and current, temperature, frequency, and strain gage inputs. Select from 8 different output options, none, Hi/Lo set point, analog, RS232, RS485, or a combination. (see order details at the bottom of this page)
A6000 Common Specifications
Specifications
Main Display Red LED 20 mm high
Sub Display Green LED 6 mm high
Conversion Rate 1000/sec
Maximum Display 9999
Over-range indication displays "OVER" or "-OVER"
Zero Display Leading "zero" suppression
Decimal point Set to any position
Operating Temperature 0~ 50° C, 35 - 85% RH
Storage Temperature -10 ~+70° C, < 60% RH
Power Supply AC 100 - 240 Volts (AC Main Unit) +/-10%
DC 12 - 48 V ) DC main unit ) +/-10%
Power Consumption ~ 8VA (max load)
Dimensions mm 96 x 48 x 97.5
Weight 450 g
Dielectric strength (AC)Power supply/ input terminal/ output terminal - AC 1500V 1minute
(DC)Input terminal /output terminal - DC 500 V 1 minute
(Common) case/each terminal AC1500 V/min
Insulation resistance DC 500V more than 100 MOhm at above terminals
 
 INPUT MODULES
*Base prices include input module, and single display. These are ready to use meters powered by AC voltage. To add output options or change the power supply, choose from options below or follow the links to the store configurator*
   
 
Thermocouple & Resistance Thermometer
Code 8 Range Sensor Type Measurement Range Max Resolution Accuracy (23ºC +/-5ºC, 35-85% RH)
  KA K -50 to 199.9ºC 0.1ºC +/-(0.5% of FS)
  KB K -50 to 1200ºC 1ºC +/-(0.2% of FS)
  J J -50 to 1000ºC 1ºC +/-(0.2% of FS)
  T T -50 to 400ºC 1ºC +/-(0.6% of FS)
  S S 0 to 1700ºC 1ºC +/-(0.4% of FS)
  R R -10 to 1700ºC 1ºC +/-(0.4% of FS)
  B B 100 to 1800ºC 1ºC +/-(0.4% of FS)
  PA PT100 ohm -100 to 199.9ºC 0.1ºC +/-(0.15% of FS)
  PB PT100 ohm -100 to 600ºC 1ºC +/-(0.4% of FS)

 


Output Modules
Analog Output (isolated from input (LO))
Any display range to output analog signal can be set
Output Method PWM
Scaling Digital Scaling
Output Resistive load Accuracy
23 degs C +/- 5 degs
Ripple
0 to 1 V > 10 KOhms +/- 0.5% full scale 50 mV p-p
0 to 10 V > 10 KOhms
1 to 5 V > 10 KOhms
4 - 20 mA less than 550 Ohms 25 mV p-p
 
External Control

Start/Hold : Shorted between COM terminal and start/hold terminal or same level --> hold Open COM terminal and start/hold terminal or 5 V --> start
D. ZERO : Shorted between COM terminal and D.ZERO terminal --> ON
P.HOLD : Shorted between COM terminal and P. HOLD terminal --> ON
R.RE (relay reset) : Shorted between COM terminal and R.RE terminal --> ON
P.SEL1 to 3 : as below

pattern 1 pattern 2 pattern 3 pattern 4 pattern 5 pattern 6 pattern 7 pattern 8
P.SEL1
OFF ON OFF ON OFF ON OFF ON
P.SEL2 OFF OFF ON ON OFF OFF ON ON
P.SEL3 OFF OFF OFF OFF ON ON ON ON
ON : Shorted between COM terminal and P.SEL terminal or same level
OFF : Open between COM terminal and P.SEL terminal or 5 V

Hi - Lo Set Point with relay output module
Control Method Computation by microcomputer
Measuring range
comparison
high/Low limit setting including polarity, -9999 to + 9999
Setting condition By sampling period
No setting condition for set value
Comparison Conditions  
Indication > High setpoint HI
High set point >/= indication>/= Lo Set point GO
Indication< Lo set point LO
Comparison Relay
contact capacity
240 Volts AC 8A resistive load
30 Volts DC 8 A resistive load
Photo-coupler output sink current 20 mA max )less than 30 V.
Output saturation voltage < 1.2 Volts at 20 mA
Hysteresis Settable from 1 to 9999 digits for each comparison set value
      
RS232 output module for A6000 DPM
Communication method Full duplex
Synchronous method Start and Stop
Transmission speed /4800/9600/19200/38400 bps
Start Bit 1 Bit
Data length 7 Bit /8 Bit
Error detection Even /odd parity
Stop Bit 1 / 2 Bits
Character Code ASC II
Transmission control none
 
RS485 output module for A6000 DPM
Communication method Full Duplex
Synchronous method Start and Stop
Transmission speed /4800/9600/19200/38400 bps
Start Bit 1 Bit
Data length 7/8 Bit
Parity Even/odd parity
Error detection BCC (Block Check Character) Check sum
Stop Bit 1/2Bits
Character Code ASC II
Transmission control none
Signal Name Signal Direction
Non-reversible output + Input/output
Reversible output - Input/output
Number of connectable meters Up to 31 units
cable length up to 500 m in total
   
Ordering Information
A6000-x-y-z-AA Construct the part numbers by adding the numbers below. The base prices given above include the input board for the ranges shown as well as a single display and a power supply board. view shopping cart
Affix x select main board power (How the unit is going to be powered)
1=AC 100-240V (standard AC outlet )
2=DC 12-48V
Add
$0
$32.00
 
Affix y Select Display 
1= single display, 
2= multiple display for Hi/Lo set point
Add
$0
$37.00
 
Affix z

Select Output Type
0 = None
1 =External Control
2 = BCD Output (TTL)
3 = BCD Output (open collector)
4 = Analong Output
5 = RS-232C
6 = RS-485
7 = RS-232C, analog output
8 = RS-485, analog output

Comparator Output:

0 none
1. Relay
2. Photocoupler

 

1= $46
2 = $77
3 = $77
4 = $42
5- $86
6 = $110
7= $138
8= $153

1=$46
2=$31

 

 
Affix AA
You can click on a code to configure and purchase online.
Codes 8 Temperature  

Other Meters( A6000)

Select Input type
Code 1 =DC Voltage ± 99.99 mV - 99.99 V - 700V
Code 2 = DC Current ±99.99 uA - 99.99 mA
Code 3 = DC Current ±9.999 mA±2A
Code 4 = AC Voltage RMS 99.99 mV - 700V
Code 5 = AC Current RMS 99.9 uA - 99.99mA
Code 6 = AC Current RMS 999.9 mA - 5A
Code 7 = Resistance Meter
Code 8 =Thermocouple
Code 9 = Tachometer
Code A = Strain
Code B = Process/Comparatorl

Other Meters( A6000)
Code 9 Tachometer
Codes 8 Temperature

Code A Strain gage

   
 