A1000 series Digital Panel Meters DC /AC Voltage/Current /Process Parameters |
![]() |
Digital panel meters from Asahi Keiki offer impressive specifications, reliability and low cost for a variety of applications |
![]() |
Features
|
The
A1000 is a modular panel meter system with a selection of input options to suit your application. Choose from 8
different input configurations for AC, DC, Voltage and current, and temperature,
inputs. |
A1000 Common Specifications |
Specifications | |
Display | Red LED 14.2 mm high |
Conversion Rate | 12.5 /sec |
Maximum Display | 1999 |
Over-range indication | '1999' LED flashes |
Operating Temperature | 0~ 50° C, 35 - 85% RH |
Storage Temperature | -10 ~+70° C, < 60% RH |
Power Supply | AC 90 - 132 Volts AC 180 - 264 Volts DC 5 - 24 V |
Power Consumption | 1.5A AC powered 100mA DC powered |
Dimensions mm | 96 x 48 x 53 mm |
Weight | 250 g |
Maximum Display | +/- 99999 ( 5 digits ) |
Decimal point | set to any position |
Dielectric strength AC | Power supply/ input terminal
- AC 1500V 1minute Power supply/ input terminal - DC 500 V 1 minute |
Insulation resistance | DC 500V more than 100 MOhm at above terminals |
INPUT Options |
DC Voltage |
Range Code |
Range | Input Impedance |
Input Protection | Accuracy 23°C±5°C 35-85% RH |
||
11 | ± 199.99 mV | 1 MOhm | ± 100V | ±(0.3% of FS) | $215.00 |
Range Code |
Range | Input Impedance |
Input Protection | Accuracy 23°C±5°C 35-85% RH |
||
12 | ±1.999 V | 1 MOhm | ± 100V | ±(0.3% of FS) | $215.00 |
|
13 | ±19.99 V | ± 250V | ||||
14 | ±199.9 V | ± 500V |
DC Current |
Range Code |
Range | Input Impedance |
Input Protection | Accuracy 23°C±5°C 35-85%RH |
||
23 | ±19.99 mA | 10 Ohm | ± 100 mA | ±(0.5% of FS) | $245.00 |
|
24 | ±199.9 mA | 1Ohm | ± 500 mA | |||
25 | ±1.999 A | 0.1Ohm | ±3A |
AC Average Voltage input frequency 40-100Hz |
Range Code |
Range | Input Impedance |
Input Protection | Accuracy 23°C±5°C 35-85%RH |
||
12 | ±1.999 V | 1 MOhm | ± 100V | ±(0.5% of FS) | $245.00 |
|
13 | ±19.99 V | ± 250V | ||||
14 | ±199.9 V | ± 500V |
AC Average Current input frequency 40-100Hz |
Range Code |
Range | Input Impedance |
Input Protection | Accuracy 23°C±5°C 35-85%RH |
||
23 | ±19.99 mA | 10 Ohm | ± 100 mA | ±(1.0% of FS) | $261.00 |
|
24 | ±199.9 mA | 1Ohm | ± 500 mA | |||
25 | ±1.999 A | 0.1Ohm | ±3A |
Process Paramaters, 1V or 2A |
![]() |
Ordering Information |
Topac Inc. 231 CJC Highway, Suite 103
Cohasset MA 02025 USA
Tel: 781 740 8778 Fax: 781 740 8779
e-mail:
sales@topac.com
| Home | E-mail | Online store | Inquiry form | Related |
This is a world wide web document page design
layout and HTML code copyright ©-2019 by Topac Inc. - ALL RIGHTS
RESERVED